+607-5546088, +6016-7725628 marketing@sensorik-auto.com


Sensorik Automation Sdn Bhd
22, Jalan Shahbandar 2, Taman Ungku Tun Aminah, 81300 Iskandar Puteri, Johor, Malaysia.
+607-5546088
+6016-7725628

STR1-SASU0AC5 Non-contact safety switches SICK | Sensorik Automation SB

Previous 5 / 15 Next

STR1-SASU0AC5 Non-contact safety switches SICK | Sensorik Automation SB Non-contact Safety Switches Safety Switches SICK
Quantity
Add Quotation


Download Files

dataSheet_STR1-SASU0AC5_1072709_en.pdf (502.13 KB)
Non-contact safety switches |
 
STR1
  • System part: Sensor and actuator
  • Actuator design: Standard
  • Coding: Uniquely coded
  • Safe switch on distance Sao10 mm
  • Connection type Detail: Cable with plug M12, 5-pin
  • Length of cable: 0.2 m
  • Safe series connection: With Flexi Loop (with diagnostics)
  • Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs)
  •  
  • Features
    System part Sensor and actuator
    Sensor principle Transponder
    Number of safe outputs 2
    Auxiliary contact (AUX) 1 (Switching behavior complementary to OSSDs)
    Safe switch on distance Sao 10 mm (–30 °C ... +70 °C) 1)
    Safe switch off distance Sar 25 mm 1)
    Active sensor surfaces 3
    Actuation directions 5
    Coding Uniquely coded
    • 1) Values apply for the frontal alignment of the sensor to the actuator. A detailed display of the alignment options and values can be found in the operating instructions.
    •  
    • Technical drawings

       
      STR1-SASU0AC5
      Dimensional drawing Sensor with cable and male connector
      STR1-SASU0AC5
      Dimensional drawing ''Standard'' actuator
      STR1-SASU0AC5
      Response range ''Standard'' actuator, active front sensor surface
       
      STR1-SASU0AC5
      Response range ''Standard'' actuator, active side sensor surface
      STR1-SASU0AC5
      Connection diagram
      STR1-SASU0AC5
      Connection single sensor
       
      STR1-SASU0AC5
      Series connection with Flexi Loop (with diagnostics)
      STR1-SASU0AC5
      Connection diagram STR1 transponder safety switch to RLY3-OSSD2 safety relay
      STR1-SASU0AC5
      Connection diagram Parallel connection of two STR1 transponder safety switches to a Flexi Classic safety controller

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter