+607-5546088, +6016-7725628 marketing@sensorik-auto.com


Sensorik Automation Sdn Bhd
22, Jalan Shahbandar 2, Taman Ungku Tun Aminah, 81300 Iskandar Puteri, Johor, Malaysia.
+607-5546088
+6016-7725628

KTL180-ME/MF/ML/MM Contrast sensors SICK | Sensorik Automation SB

Previous 29 / 33 Next

KTL180-ME/MF/ML/MM Contrast sensors SICK | Sensorik Automation SB Contrast Sensors Registration Sensors SICK
Quantity
Add Quotation


Download Files

KTL180-MM4P41ZZZZZ.pdf (657.92 KB)
KTL180-ML4P41ZZZZZ.pdf (657.88 KB)
KTL180-MF2P41ZZZZZ.pdf (671.11 KB)
KTL180-ME2P41ZZZZZ.pdf (670.78 KB)
Contrast sensors |
 
KTL180
  • Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
  • Light source: LED, White
  • Sensing distance: 1,400 mm
  • Switching output: NPN
  • Connection type Detail: Male connector M8, 4-pin
  • Device type: Expansion unit
  •  
  • Features
    Special applications -
    Device type Expansion unit
    Indication Display
    Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
    Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm
    Sensing range 0 mm ... 1,400 mm, Proximity system 1)
    Sensing distance 1 mm, 1,400 mm 1)
    Housing design (light emission) Rectangular
    Light source LED, White 2)
    Angle of dispersion Approx. 65° 3)
    Wave length 400 nm ... 750 nm
    Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic
    Delay time Adjustable
    Special features Multi-function input, no L+/M, expansion unit for BUS mode
    Delivery status Teach-in dynamic
    Parameter presettings None
    • 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
    • 2) Average service life: 100,000 h at TU = +25 °C.
    • 3) See LL3 fiber-optic data.
    • Technical drawings

       
      KTL180-ME2P41ZZZZZ
      Dimensional drawing Expansion unit
      KTL180-ME2P41ZZZZZ
      Adjustments
      KTL180-ME2P41ZZZZZ
      Connection diagram Cd-380
       
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DZ01
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA09)
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
       
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DC38
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DB09, LL3-DK04, LL3-DY01
       
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DB01, LL3-DB04, LL3DM02
      KTL180-ME2P41ZZZZZ
      Sensing distance LL3-DC09
  •  

Contrast sensors |
 
KTL180
  • Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
  • Light source: LED, White
  • Sensing distance: 1,400 mm
  • Switching output: PNP
  • Connection type Detail: Male connector M8, 4-pin
  • Device type: Expansion unit
  •  
  • Features
    Special applications -
    Device type Expansion unit
    Indication Display
    Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
    Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm
    Sensing range 0 mm ... 1,400 mm, Proximity system 1)
    Sensing distance 1 mm, 1,400 mm 1)
    Housing design (light emission) Rectangular
    Light source LED, White 2)
    Angle of dispersion Approx. 65° 3)
    Wave length 400 nm ... 750 nm
    Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic
    Delay time Adjustable
    Special features Multi-function input, no L+/M, expansion unit for BUS mode
    Delivery status Teach-in dynamic
    Parameter presettings None
    • 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
    • 2) Average service life: 100,000 h at TU = +25 °C.
    • 3) See LL3 fiber-optic data.
    • Technical drawings

       
      KTL180-MF2P41ZZZZZ
      Dimensional drawing Expansion unit
      KTL180-MF2P41ZZZZZ
      Adjustments
      KTL180-MF2P41ZZZZZ
      Connection diagram Cd-380
       
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DZ01
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA09)
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
       
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DC38
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DB09, LL3-DK04, LL3-DY01
       
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DB01, LL3-DB04, LL3DM02
      KTL180-MF2P41ZZZZZ
      Sensing distance LL3-DC09
  •  
Contrast sensors |
 
KTL180
  • Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
  • Light source: LED, White
  • Sensing distance: 1,400 mm
  • Switching output: NPN
  • Connection type Detail: Male connector M8, 4-pin
  • Device type: Base unit
  •  
  • Features
    Special applications -
    Device type Base unit
    Indication Display
    Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
    Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm
    Sensing range 0 mm ... 1,400 mm, Proximity system 1)
    Sensing distance 1 mm, 1,400 mm 1)
    Housing design (light emission) Rectangular
    Light source LED, White 2)
    Angle of dispersion Approx. 65° 3)
    Wave length 400 nm ... 750 nm
    Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic
    Delay time Adjustable
    Special features Multi-function input, base unit for BUS mode
    Delivery status Teach-in dynamic
    Parameter presettings None
    • 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
    • 2) Average service life: 100,000 h at TU = +25 °C.
    • 3) See LL3 fiber-optic data.
    • Technical drawings

       
      KTL180-ML4P41ZZZZZ
      Dimensional drawing Bus type
      KTL180-ML4P41ZZZZZ
      Adjustments
      KTL180-ML4P41ZZZZZ
      Connection diagram Cd-380
       
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DZ01
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA09)
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
       
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DC38
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DB09, LL3-DK04, LL3-DY01
       
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DB01, LL3-DB04, LL3DM02
      KTL180-ML4P41ZZZZZ
      Sensing distance LL3-DC09
  •  

Contrast sensors |
 
KTL180
  • Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
  • Light source: LED, White
  • Sensing distance: 1,400 mm
  • Switching output: PNP
  • Connection type Detail: Male connector M8, 4-pin
  • Device type: Base unit
  •  
  • Features
    Special applications -
    Device type Base unit
    Indication Display
    Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters
    Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm
    Sensing range 0 mm ... 1,400 mm, Proximity system 1)
    Sensing distance 1 mm, 1,400 mm 1)
    Housing design (light emission) Rectangular
    Light source LED, White 2)
    Angle of dispersion Approx. 65° 3)
    Wave length 400 nm ... 750 nm
    Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic
    Delay time Adjustable
    Special features Multi-function input, base unit for BUS mode
    Delivery status Teach-in dynamic
    Parameter presettings None
    • 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
    • 2) Average service life: 100,000 h at TU = +25 °C.
    • 3) See LL3 fiber-optic data.
    • Technical drawings

       
      KTL180-MM4P41ZZZZZ
      Dimensional drawing Bus type
      KTL180-MM4P41ZZZZZ
      Adjustments
      KTL180-MM4P41ZZZZZ
      Connection diagram Cd-380
       
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DZ01
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA09)
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
       
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DM02 (LL3-DA06)
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DC38
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DB09, LL3-DK04, LL3-DY01
       
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DB01, LL3-DB04, LL3DM02
      KTL180-MM4P41ZZZZZ
      Sensing distance LL3-DC09

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter